SA-P8 sounder

SA-P8 SOUNDER HOLDS DOCUMENTS ISSUED BY CNBOP-PIB:

  • CERTIFICATE CPR NO. 1438-CPR-0883
  • CERTIFICATE OF APPROVAL NO. 4839/2023

ATTENTION! Documents to be downloaded after logging in to the Client Zone

Use:

The SA-P8 sounder is intended for signalling of fire inside buildings.


Construction:

The signalling device is equipped with housing made of non-combustible material, enclosing electronic components. Acoustic signals are generated by means of piezoceramic transducer, located inside the housing. The cover of SA-P8 sounders holds supply block, WSD switch block and micro switch, by means of which operating mode of the signalling device, as well as acoustic signal type can be selected.


Operating design:

After connecting the supply voltage, the SA-P8 sounder generates an acoustic signal in accordance with the current settings. The acoustic signal is generated by a piezoceramic transducer. The SA-P8 sounder enables the creation of a network of synchronously operating sounders.


Varieties:

The SA-P8 sounder is available in 2 varieties.

Varieties Description
SA-P8/C sounder in red housing
SA-P8/B sounder in white housing

Opening:

To open the alarm device you should: screw out the blocking screw, twist the shade to the left while holding the base, then move apart the shade and the base.

Closing:

To close the alarm device adjust the markers, then assemble the device and twist it to the direction marked with an arrow (sequence shown in the drawing). After closing, screw in the blocking screw.


Assembly recommendations:

The SA-P8 sounders should be connected to the FAS installation through junction boxes with the required class of maintaining electrical functions (recommended PIP-3AN). If there is no need to use the synchronization option of the SO-P8 VADs, it is also possible to mount them through the PIP-1AN installation box, observing the following information on the mounting method. If mounting directly on the box is not required, the PIP-2AN/0.375A box can be used to connect the device.

The box should be mounted to the substrate/wall with the required fire resistance. If, for aesthetic reasons, it is not possible to mount the signaling device directly on the PIP box, it is permissible to mount the signaling device to the base that does not have the required fire resistance, while the PIP junction box must be mounted on the base with the required fire resistance (e.g. a situation in which the box PIP is mounted to the ceiling with E90 resistance, while the SA-P8 sounder is mounted in the suspended ceiling). Detailed guidelines for the installation of PIP installation boxes are included in the National Technical Assessment CNBOP-PIB-KOT-2019/0113-3704 edition 2.

The mounting cover OM-1 is intended for installation in a suspended ceiling. This procedure allows the device to be hidden in the suspended ceiling, which increases the aesthetic value of the installation.

If there is a need to protect the signaling device against mechanical damage at the installation site, the OZ-50-3 protective cover can be used.

Type sounder
Supply voltage 16-32,5 V DC
Current consumption in off state 0 mA
Current consumption in on state <40 mA*
Power consumption in on state <0,96 W*
Sound output >100 dB*
Flash frequency not applicable
Flash time not applicable
Time between flashes not applicable
Device category not applicable
Device type type A
Working temperature from -10°C to +55°C
IP protection degree IP33
IK protection degree IK07
Conductor cross-section 2,5 mm2
Dimensions Ø114×88 mm
Weight ~235 g

*for default settings
(supply voltage Uz=24V DC, fire service signal, potentiometer maximum, optional gradual volume increasing – ON)

Control:

Connecting the supply voltage to the appropriate terminals triggers the acoustic alarm signal.

 

Number of microswitch Mark Function
1 M/S Operating mode selection MASTER (ON) / SLAVE (OFF)
2 S0 Sound pattern selection
3 S1 Sound pattern selection
4 S2 Sound pattern selection
5 S3 Sound pattern selection
6 VR Optional gradual volume increasing (ON)

Control – devices network:

SA-P8 sounder can work in a network. Devices that are to be synchronized with each other should be connected with an additional conductor marked as S. Only one device in the network should be set as MASTER, the rest as SLAVE.

The figure below shows an example of a SA-P8 synchronization scheme.

Activation of the WSD-1 switch connected to the MASTER device silences the entire line of devices operating in the network. Activation of the switch connected to the device operating in the SLAVE mode turns off the acoustic part only in the device to which the WSD-1 is connected.

NOTICE!

Adjusting the sound level by means of a potentiometer works locally and applies to the signaling device in which the setting is changed.

NOTICE!

SA-P8 devices can also be synchronized with other signaling devices produced by W2:

  • SA-K5N / acoustic part
  • SA-K7N oraz SAOZ-Pk2 / acoustic part

 

Cooperating products

OZ-50-3 cover

OZ-50-3 protective cover

Intended use: The OZ-50-3 covers are intended to protect signalling devices with optical part, detectors or other devices that match…

OM-1 mounting sleeve

Use: Mounting Sleeves OM-1 are used to mount the signalling devices manufactured by the W2 company in suspended ceilings, coffered…

wyłącznik akustyczny pożarowego sygnału dźwiękowego

WSD-1 audible signal switch

Use: The WSD-1 audible signal switch is destined for collaboration with: sounders type SA-K5, SA-K6, SA-K7 sounders type SA-P8, sounders…

PIP-1AN cable distribution junction box

PIP-1AN cable distribution junction box

PIP-1AN CABLE DISTRIBUTION JUNCTION BOX HOLDS DOCUMENTS ISSUED BY CNBOP-PIB: THE NATIONAL CERTIFICATE OF CONSTANCY OF PERFORMANCE NO. 063-UWB-0194 NATIONAL…

puszka instalacyjna PIP-1AN

PIP-3AN cable distribution junction box

PIP-3AN CABLE DISTRIBUTION JUNCTION BOX HOLDS DOCUMENTS ISSUED BY CNBOP-PIB: NATIONAL CERTIFICATE OF CONSTANCY OF PERFORMANCE NO. 063-UWB-0194 NATIONAL TECHNICAL…

Choose language